Integra-lifesciences Cervical Dilator Set, Reusable User Manual

Browse online or download User Manual for Health and hygiene Integra-lifesciences Cervical Dilator Set, Reusable. Integra LifeSciences Cervical Dilator Set, Reusable User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Description
Cervical dilators are smooth and flexible, light in weight and can be easily
inserted and removed for their intended applications. They are made of
medical-grade Teflon and are latex-free.
The OS Locator
One molded band above the tactile handle and opposite the distal end of the
device identifies the disposable OS locator. The OS locator may be used to
find and gently dilate the external OS. The OS locator offers gradual dilation,
tip flexibility, and a smooth surface. The OS locator is tapered 23 mm to an
intermediate diameter of 3.8 mm.
The Canal Dilator
Two molded bands above the tactile handle identify the canal dilator from the
OS locator and the fundus sound. Its longer tapered tip is 45 mm and extends
to an intermediate diameter of 3.8 mm. The canal dilator may be used to slowly
dilate the length of the cervical canal.
The Fundus Sound
Three molded bands opposite the distal tip identify the fundus sound from the
others as described above. The tapered length from the distal tip is 85 mm. The
smooth and flexible fundus sound is designed to pass through the entire length
of the cervix, dilate the internal OS and sound the fundus to determine
uterine depth.
Indications
Cervical dilators are useful in locating and dilating the external OS, cervical
canal and internal OS of the uterus. Cervical dilators may be used on post-
menopausal patients with cervical stenosis.
Contraindications
Cervical dilators should not be used under the following conditions:
• Acutegenitaltrackorpelvicinfections.
• Apregnancyorthesuspicionofapregnancy.
• Anyinvasivecancerthatisvisibleuponexamination.
• Anynon-compliantpatient.
Warnings
This procedure should only be performed by a trained medical professional.
The use of excessive force should be avoided.
Cervical dilators should not be used for prolonged periods of time.
Precautions
• Reusablecervicaldilatorsetisprovidednon-sterile.
Dilators must be sterilized prior to use.
• Visuallyinspectthedilatorsforanysurfacedamagepriortouse.
• Dilatorsthataredamagedmustnotbeused.
Instructions
Dilation of the cervix may be required for many diagnostic and treatment
procedures. This procedure should always be performed by a medical professional
whoistrainedintheprocedureandawareofallpossiblecomplicationsandrisks
that may be present.
1.Apelvicexaminationofthepatientshouldbeperformedpriortodilationto
 determineconditionspresentandrisksofdilation.
2. The insertion of a weighted speculum may assist with visualization of the cervix.
3. Uterine tenaculum forceps should be used to grasp the cervix. Stabilization of the
tenaculum should be maintained during the dilation procedure to absorb
resistance and avoid trauma to surrounding anatomical structures.
4. The OS locator is used to gently dilate the external OS to allow access to the
 cervicalcanal.Holdingthedilatorlikeapen,gentlyinsertthedilatorintothe
 externalOS.Slight,slowmovementscanbeusedtobreakupconnectivetissues
that may exist. Proceeding slowly allows the OS to gently stretch to
accommodate the dilator.
5. The canal dilator is oen needed next to continue the dilation of the cervical
canal to gain access to the internal OS. The canal may become atrophic and rigid
in post menopausal patients. Proceeding slowly using the technique referenced
above, allows the canal to gently stretch over the dilator.
6. The fundus sound is utilized to complete the dilation of the internal OS and
palpate the depth of the uterus. Dilation of the internal OS should also proceed
slowly to allow the tissues to gently stretch over the dilator. Continuing to hold
 thedilatorlikeapen,careshouldbeexercisedtominimizetheriskofperforation
of the uterus or tearing of the internal OS.
7. If additional dilation is required, the use of progressively larger diameter dilators
can be utilized following the same process allowing for slow dilation of the
cervix to accommodate instrumentation needed for the procedure.
8. If resistance is met to any size dilator it is advisable to leave it in the internal
OS for several seconds to allow the tissues to expand around it.
Cleaning Instructions/Sterilization Instructions
1. Cleaning: submerge in enzymatic cleaner for 20 minutes. Cleaning was validated
using MRapidMulti-Enzyme.Otherenzymaticcleanersmaybeeectivebut
have not been validated.
 Removefromenzymaticcleanerandrinsethoroughlywithwater.Demineralized
water is recommended for rinsing.
 Allowtodrycompletelypriortosterilization.
2. Disinfecting: use Cidex® disinfecting solution for 12 minutes. Follow the
disinfecting solution’s instructions for use. Other disinfecting solutions may
be effective but have not been validated.
 Removefromdisinfectingsolutionandrinsethoroughlywithdemineralizedwater.
 Allowtodrycompletelypriortosterilization.
See reverse more more information
Integra
®
Miltex
®
Reusable Cervical Dilator Set
Directions for Use / English
LOT
REF
REF
30-3000 Reusable Cervical Dilator Set
0434
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Directions for Use / English

DescriptionCervical dilators are smooth and flexible, light in weight and can be easily inserted and removed for their intended applications. They are

Page 2

3.Parametriraccomandatiperlasterilizzazione:Direive per il reso dei prodoiI prodoi devono essere restituiti in confezioni chiuse con i sigilli

Page 3

BeschrijvingCervicale oprekkers of dilatatoren zijn glad en flexibel, licht in gewicht en gemakkelijk in te brengen en te verwijderen voor het bedoelde

Page 4

3.Aanbevolensterilisatieparameters:Beleid voor retourneren van artikelenAlleenproductendieinongeopendeverpakkingenmetdeverzegelingvandef

Page 5 - Français

3.RecommendedSterilizationParameters:Returned Goods Policy Productsmustbereturnedinunopenedpackageswithmanufacturer’ssealsintact to be ac

Page 6

DescripciónLos dilatadores cervicales son suaves, flexibles, livianos y pueden insertarse y retirarse fácilmente cuando se los utiliza de acuerdo con e

Page 7 - Gebrauchsanweisung / Deutsch

3. Parámetros de esterilización recomendados:Política de devolución de productosLos productos deben devolverse en paquetes sin abrir, con los sellos d

Page 8

DescriptionLes dilatateurs cervicaux sont lisses et souples, légers et peuvent être insérés et retirés facilement pour leur application désignée. Ils

Page 9

3. Paramètres de stérilisation recommandés:Politique des marchandises retournées Les produits doivent être retournés dans des emballages non ouverts

Page 10

BeschreibungZervikaldilatatoren sind gla, flexibel und leichtgewichtig und können leicht zur beabsichtigten Anwendung eingeführt und herausgezogen wer

Page 11 - Herbruikbare Cervix Oprekset

3. Empfohlene Sterilisationsparameter:Hinweise zur Rücksendung von WarenProdukte müssen in der ungeöffneten Verpackung mit intaktem Herstellersiegel zu

Page 12

DescrizioneI dilatatori cervicali sono levigati, flessibili, leggeri e facili da inserire e rimuovere per l'applicazione per cui sono previsti. Re

Comments to this Manuals